THWN Wire: Meaning, Rating and Use
THWN wire is a single-conductor, thermoplastic-insulated building wire rated for 600 volts and approved for wet and dry locations. It is normally pulled through conduit inside walls, ceilings, slabs and outdoor runs.
This page defines the letters, explains the temperature rating, compares THWN with THHN, and lists where the wire is used, split by sizes, colors and common questions.
Key points
- THWN wire is a 600V thermoplastic-insulated conductor made for wet and dry locations, usually installed in conduit rather than run bare.
- Most wire sold today is dual-marked THHN/THWN or THHN/THWN-2, so one spool often covers dry heat and wet-location use.
- Insulation color does not tell you the gauge, so read the size printed on the jacket before you cut or connect.
- Wire selection, conduit fill and permits depend on your local code, so a licensed electrician should confirm the work.
THWN wire meaning and rating
| Term | Meaning | Why it matters |
|---|---|---|
| T | Thermoplastic insulation, a PVC-based plastic that softens when heated | It sets the wire apart from thermoset types such as XHHW-2, which use cross-linked polyethylene. |
| H | Heat resistant, rated up to 75°C in the basic form | Heat rating limits how much current the conductor may carry. |
| HH | High heat resistant, rated for 90°C in dry locations | THHN carries this rating, which helps with derating calculations. |
| W | Water resistant, approved for wet locations | It lets the wire run in underground or outdoor conduit where moisture collects. |
| N | Nylon outer jacket over the insulation | The nylon resists abrasion and oil, so the wire slides through conduit more easily. |
| 600V | Maximum voltage rating of the insulation | It covers standard 120V and 240V home circuits and most commercial building circuits. |
THWN wire uses in conduit
THWN wire is a building wire, so you find it inside raceways rather than as exposed cable. These are the common places.
- Pull individual THWN conductors through EMT or rigid conduit for branch circuits in garages, workshops and unfinished basements where the wiring must be protected from damage.
- Use it in underground PVC conduit for feeds to detached garages, sheds and pumps, where water can enter the conduit and sit around the conductors.
- Run it in outdoor conduit to air conditioner disconnects, pool equipment and well pumps, since the wet-location marking covers rain and condensation exposure.
- Install it as service and feeder conductors between the meter, the main panel and subpanels, often in larger sizes.
- Choose it for commercial and industrial wiring, including motor circuits and lighting runs in conduit, where conductors may need replacing without opening walls.
- Use smaller sizes such as 14 or 12 AWG for lighting and receptacle circuits in conduit, matching the breaker size your electrician specifies.
THWN wire vs THHN wire
| Feature | THHN | THWN |
|---|---|---|
| Insulation | Thermoplastic with nylon jacket | Thermoplastic with nylon jacket |
| Voltage | 600V | 600V |
| Dry location | Rated up to 90°C | Rated 75°C in dry locations (THWN-2: 90°C) |
| Wet location | Rated 90°C dry; not rated for wet locations on its own | Rated for wet locations |
| Typical marking | THHN | THHN/THWN or THHN/THWN-2 dual marking |
THWN wire sizes and colors
People often search for sizes such as 8 gauge, number 12 or 14 gauge wire. Size comes from the printed AWG number, not from the color.
- Read the AWG number printed along the jacket, for example 12 or 8, because THWN conductors in every size are sold in many insulation colors.
- Expect number 12 THHN to be common for 20-amp lighting and receptacle circuits, but confirm the breaker size and circuit load with your electrician.
- Treat 8 gauge THHN wire as a heavier conductor used for larger loads such as ranges, subpanel feeds or appliances, with size set by the load.
- Note that 14 gauge wire has no fixed color; on common white-sheathed nonmetallic cable the sheath is often white, but individual THWN conductors come in black, red, blue and others.
- Use green for equipment grounding, white or gray for neutrals, and black or red for hot conductors, and avoid reusing a marked conductor for another purpose.
- Allow extra room in the conduit for THWN-2, which runs roughly 10% larger in diameter than THHN of the same gauge because of thicker insulation.
Why THWN wire matters
Choosing the wrong insulation type can shorten wire life or fail an inspection. These points explain the stakes.
- Confirm the wet-location marking before a conduit run goes underground or outdoors, because THHN alone is not rated for wet locations.
- Check the temperature rating, since THHN is rated up to 90°C dry and standard THWN is 75°C, which can lower the current the conductor may carry.
- Look at the full jacket marking, because dual-marked wire such as THHN/THWN-2 is intended to satisfy both dry and wet requirements with a single product.
- Compare thermoplastic and thermoset types, since THHN/THWN-2 uses PVC insulation while XHHW-2 uses cross-linked polyethylene, and each suits different jobs.
- Plan conduit fill early, because thicker insulation and larger wire sizes limit how many conductors fit in a given conduit diameter.
- Ask your local building department about permits, since residential electrical work often needs one and the rules vary by state and city.
Terms related to THWN wire
- THHN: thermoplastic building wire rated 90°C in dry locations, often sold dual-marked as THHN/THWN for wet and dry use.
- THWN-2: an updated rating with a 90°C allowance in wet locations, found on most dual-marked wire sold today.
- XHHW-2: thermoset building wire with cross-linked polyethylene insulation, used where flexibility or heat resistance is preferred.
- AWG: American Wire Gauge, the size scale where a smaller number means a thicker conductor and higher current capacity.
- Conduit fill: the share of a conduit's cross-section that conductors may occupy, set by code to keep heat and pulling force down.
- NM-B cable: sheathed nonmetallic cable holding several insulated conductors, a different product from loose THWN conductors in conduit.
Frequently asked questions
Is THWN wire the same as THHN?
They share the same 600V thermoplastic construction and nylon jacket. THHN is rated for dry to damp locations, while THWN adds wet-location approval.
Most wire sold today carries both markings, so one product often meets either requirement.
What color is 14 gauge wire?
There is no fixed color for 14 gauge THWN conductors, which come in black, white, red, green and more. On common nonmetallic cable, the outer sheath is often white for 14 gauge.
Always read the printed size.
Can THWN wire be used outdoors?
Yes, THWN and dual-marked THHN/THWN-2 are approved for wet locations, which is why they are used in outdoor and underground conduit. Installation still needs the correct conduit, fittings and local permits, so have a licensed electrician confirm the plan.
Can I install THWN wire myself?
Rules differ by state and city, and many places require a licensed electrician or a permit for new circuits. Check with your local building department before starting.
Wrong wire size or connections can cause overheating, shock or fire.
Next step for your wiring
If you are planning conduit runs, a new circuit or a replacement of old conductors, we at Quantra Electrician can send a licensed electrician to choose the right wire type and size and complete the wiring and circuit installation. Share your project details and we will line up the visit, including advice on local permits.