Wiring & Cable: Types, Uses and Sizing Guide (2026)

Wiring & cable is the set of conductors, jackets and supports that carry power and signals through a building. This guide splits cable types by location and job, from interior circuits and outdoor runs to older homes, cost and extension cords.

Key points

  • Pick cable by location first: dry interior, buried outdoor, low-voltage or data runs each use a different cable type and jacket.
  • Match conductor size to the breaker and the load. A cable that is too small for the circuit is a fire risk.
  • Permanent wiring changes usually need a permit and inspection, and rules vary by state and city, so check local requirements.
  • Panel, service and circuit work belongs to a licensed electrician. Do not DIY work inside the panel.
TermMeaningWhy it matters
NM-B cableNon-metallic sheathed cable, the standard for residential interior wiring in most dry locations.It is the cable behind most walls in a house, so it is the one you will meet most often.
UF-B cableCable with a solid PVC jacket molded around the conductors, rated for direct burial.It handles moisture and soil contact that would ruin standard interior cable.
Cat6 cableTwisted-pair data cable used for wired network connections.Pulling it too hard or bending it too tightly can degrade the signal.
Bend radiusThe tightest curve a cable can take without damage. For low-voltage cable, keep at least 4 times the cable diameter.Tight bends damage insulation and conductors, especially in crowded boxes and tray runs.
240V circuitA higher-voltage circuit from 120/240V single-phase service, used for high-draw appliances.These circuits need heavier cable and a matching breaker.

Wiring & cable for interior home circuits

Most interior circuits in a house run on NM-B cable, with 120V for outlets and lighting. These six points cover choosing and routing it.

  1. Use NM-B cable for dry interior runs inside walls, ceilings and floors, since it is the standard residential choice and allowed in most interior dry locations.
  2. Match the cable gauge to the breaker on that circuit, and have a licensed electrician confirm the pairing before you add loads to an existing run.
  3. Staple or strap cable at regular intervals and keep it snug to framing, so it does not sag or rub against sharp edges.
  4. Drill holes in the center of studs where you can, and ask your electrician about protection plates where cable runs close to the face.
  5. Leave enough slack in each box to make connections cleanly, and do not cram excess cable behind devices where it can get pinched.
  6. Keep 120V lighting and outlet circuits separate from 240V appliance circuits, and label every breaker so the next person can trace each cable.

Wiring & cable for outdoor and underground runs

Outdoor cable faces moisture, sun and soil. Use a type with the right jacket and bury it to the right depth.

  1. Choose UF-B cable for direct burial, since its solid PVC jacket is molded around the conductors and sheds moisture that would soak into interior cable.
  2. Bury UF-B at a minimum of 24 inches deep under the usual NEC rule, with a shallower depth allowed in some cases such as under a slab; confirm with local rules.
  3. Check with your local building department before trenching, because depth, conduit and permit rules differ by state and city.
  4. Call your local utility locate service before you dig, so you do not strike a gas line, water line or buried power feed.
  5. Keep outdoor splices inside listed, weatherproof boxes and fittings, and do not bury a splice made with indoor-rated connectors.
  6. Leave a drip loop where a cable enters a building or fixture from above, so water runs off instead of tracking inside.

Wiring & cable for 240V and high-draw appliances

Ranges, dryers, EV chargers and similar loads use 240V circuits. Read our guide on what size wire for 50 amp circuits before you buy any cable.

  1. Treat 240V circuits as separate runs from 120V circuits, since high-draw appliances pull far more current and heat up undersized cable quickly.
  2. Size the conductor from the appliance nameplate and the breaker rating, and ask a licensed electrician to confirm the gauge for the length of your run.
  3. Use the cable type your local rules allow for the location, such as NM-B indoors in dry spaces or a different method in exposed areas.
  4. Expect long runs to need a larger conductor than short ones, because voltage drop increases with distance and load.
  5. Do not tap an existing circuit to feed a new large appliance, since that can overload the cable and the breaker behind it.
  6. Leave all panel connections and breaker installation to a licensed electrician, and arrange the permit and inspection before the walls are closed.

Wiring & cable for thermostats and low voltage

Thermostat and control wiring runs at low voltage, with thin multi-conductor cable. The points below apply to most thermostat and control runs.

  1. Use multi-conductor thermostat cable with enough conductors for your system, and count the wires you need before you buy a length.
  2. Keep low-voltage cable at least 4 times its own diameter in bend radius, so the insulation and conductors are not stressed at corners.
  3. Separate low-voltage runs from line-voltage cable where you can, and cross power cable at right angles instead of running parallel.
  4. Turn off the system at the breaker before you disconnect any control wires, and photograph the terminals before you pull anything.
  5. Label each conductor at both ends with its terminal letter, so a later swap or upgrade does not rely on memory.
  6. Stop and call a licensed electrician if you find cut insulation, scorch marks, a burning smell or any line-voltage conductor at the thermostat.

Wiring & cable for data and network runs

Cat6 is the common data cable for wired networks. It is sensitive to handling, so treat it gently during the pull.

  1. Pull Cat6 with steady, light force and stay below about 25 lbs of pull, subject to the manufacturer specifications on the box.
  2. Hold the bend radius to at least 4 times the cable diameter at every turn, including inside boxes and behind wall plates.
  3. Run data cable away from parallel power cable where possible, since close runs next to line-voltage wiring can add interference.
  4. Do not staple through or crush the jacket. Use loose, cable-rated supports so the twisted pairs keep their geometry.
  5. Test each run after termination, and label both ends with the jack number so you can find a faulty run later.
  6. Use a cable tray for bundles in basements or commercial spaces, so the routes stay supported and the bend radius is easy to hold.

Wiring & cable for garages and workshops

Garages and workshops combine tools, moisture and vehicles. That makes cable choice and protection more important than in a bedroom.

  1. Plan one dedicated circuit for each large stationary tool, so a table saw and a compressor do not share one cable.
  2. Protect exposed cable on garage walls where it can be struck, and ask your electrician about conduit for those sections.
  3. Keep cable away from heat sources such as water heaters, furnace flues and lighting fixtures that run hot.
  4. Check where cable passes through a wall between the garage and the house, since fire-separation rules may apply and vary locally.
  5. Choose a sub-panel only through a licensed electrician, who will size the feeder cable and the breaker for your load.
  6. Check with your local building department about a permit before adding circuits, because inspectors may review garage work for cable type, protection and breaker pairing.

Wiring & cable for older homes and rewiring

Older homes may have cable that is brittle, undersized or missing a ground. A licensed electrician can test it and advise whether to repair or replace.

  1. Look for cracked or crumbling insulation at outlets, switches and in the attic, since those are the places where old cable shows its age.
  2. Treat flickering lights, warm cover plates and repeat breaker trips as signs to have the circuits inspected soon.
  3. Do not add new loads to old cable on the assumption that it can carry them, because ratings depend on the cable and its condition.
  4. Expect plaster and lath walls, fire blocking and tight attics to slow a rewire and raise the labor share of the job.
  5. Ask about a service upgrade at the same time, since new single-family homes typically get a 200-amp service, though requirements vary by jurisdiction.
  6. Do not DIY work you cannot de-energize. Call a licensed electrician if you find exposed wires, a burning smell or a shock.

Our guide to the average cost to rewire a house breaks down what changes the total.

Wiring & cable cost and permits

Cable cost depends on the length, the cable type and how hard the route is to reach. Permits are a separate item.

Permit fees for residential electrical work typically range from $50 to $500 depending on the scope of work.

  1. Longer runs cost more because they use more cable and more labor hours, and attic or crawlspace routes add time.
  2. Finished walls cost more than open framing, since the electrician must fish cable and patch access holes afterward.
  3. Heavier conductors for 240V loads cost more per foot than light-gauge cable for lighting circuits.
  4. A panel or service upgrade adds to the job, so ask whether your cable work needs one before you compare quotes.
  5. Permit and inspection requirements vary by state and city, so check with your local building department before work begins.
  6. Get at least two written quotes that list cable type, run length, permit handling and what is included in the price.

Wiring & cable vs extension cords

An extension cord is a temporary connection, while building cable is permanent. Choose a cord rated for its location and keep it out of walls.

FeatureBuilding wiring & cableExtension cord
UsePermanent circuits inside walls, ceilings and undergroundTemporary power to a tool or device
InstallationFixed, supported and often permitted and inspectedPlugged in and moved as needed
Who installs itA licensed electrician or a permitted homeowner, depending on local rulesYou
Location limitsCable type must match dry, wet or buried locationsUse an outdoor-rated cord outside, and do not run it through walls or under rugs
Risk if misusedHidden overheating inside wallsOverheated cord, tripping and damaged insulation

Best practices for wiring & cable

Check the cable type against the location

Read the printing on the jacket and match it to the place the cable will run. A dry-location cable in a wet or buried run is a common cause of failure.

Size the conductor for the breaker

The breaker protects the cable, so the two have to match. Ask a licensed electrician to confirm the pairing before adding any load to an existing circuit.

Protect the jacket during the pull

Pull steadily and avoid sharp edges, since a nicked jacket may not show a problem until years later. For data cable, stay below about 25 lbs of pull.

Respect bend radius

Do not kink cable around corners or force it into a tight box. Keep low-voltage cable to at least 4 times its diameter.

Label every run

Mark both ends and the breaker with the room and purpose. Clear labels save time on every future repair, inspection and upgrade.

Frequently asked questions

What is the difference between wire and cable?

Wire is a single conductor, often insulated, while cable is two or more conductors grouped inside one jacket. NM-B and UF-B are cables, and a single insulated conductor pulled through conduit is wire.

Can I bury NM-B cable in the yard?

No, because NM-B is made for dry interior locations. For direct burial, use UF-B cable at the depth your local code requires (commonly 24 inches), and check local rules first.

How do I know which cable my house has?

Check the printed jacket in an accessible spot such as the attic or near the panel. If markings are worn or unclear, a licensed electrician can identify the cable and test its condition.

Do I need a permit to run new cable?

Often yes for permanent wiring changes, but rules vary by state and city. Contact your local building department before starting, and ask whether an inspection is required.

How hard can I pull data cable?

For Cat6, keep pulling force below about 25 lbs, subject to the manufacturer specifications. Keep bends at least 4 times the cable diameter, and avoid kinks, crushing and sharp edges.

What should I do if I see exposed wires or smell burning?

Stay away from the area, do not touch the wires, and call a qualified electrician right away. If you smell burning or feel a shock, switch off power only if it is safe to reach the panel.

Next step for your wiring & cable project

If you are unsure which cable fits your project, or you have found damaged cable, we can send a licensed electrician. They can check the run, match cable to breaker and explain permit steps in your area.